PC-R9 series HAST Chambers - PC-304R9/422R9​​

hast
  • Fully programmable, high precision, controller allows you to control every feature of the system easily.

  • Chamber sizes (useable)

    • PC-304R9: ø220mm x D 350mm​

    • PC-422R9: ø340mm x D 475mm​

  • 2 Control Modes: Unsaturated​ & Saturated

  • High Performance Dual Chamber System

    • Independent chambers for test and steam generation, giving more stable control than single chamber systems.

  • Working Temperature Range

    • PC304R9

      • 105.0~151.4ºC @ 100%RH

      • 110.0~​157.5ºC @ 85%RH

      • 118.0~162.5ºC @ 65%RH

    • PC422R9​

      • 105.0~133.3ºC @ 100%RH​

      • 110.0~140.0ºC @ 85%RH

      • 118.0~150.0ºC @ 65%RH

  • Working Pressure Range

    • PC304R9: 0.019 ~ 0.393MPa​

    • PC422R9: 0.019 ~ 0.208MPa

  • Temperature Control Accuracy: ±0.5ºC​

  • Working Humidity Range: +65 to 100%RH

  • Humidity Control Accuracy: ±3% @ 85%RH

  • Selectable Exhaust modes

    • Slow Cooling with humidity maintained​

    • Cooling with moisture maintained

    • Quick Exhaust

  • Cleaning mode

  • Remote operation via LAN or Wifi

  • Air-HAST option

  • Continuous Operation : upto 500 hours

  • Bias Terminals: 20 (Applied voltage: 125V, within 30W in total)

  • Time Signal Termainals: 4

  • Dual Chamber "D" Model available

    • Double capacity​

    • Ability to run 2 separate test programs simultaneously

  • LED HAST system available​

    • Providing LED Life Evaluation Testing under HAST conditions to greatly reduce overall life test duration by integrating LED output measuring devices within the HAST chamber.

    • Test Channels: upto 40

    • Number of Test Channels per measuring device (LBU): 8

    • Number of measuring devices per HAST chamber: upto 5

    • Forward voltage can be measured along with light output

PC-242HSR2 Benchtop HAST Chamber​

  • High Performance Dual Chamber System

    • Independent chambers for test and steam generation, giving more stable control than single chamber systems.

  • Overall Dimensions: W 607mm x D 633mm x H 476mm

  • Chamber Size (useable): W 100mm x D 6310mm x H 100mm

  • Working Temperature Range:

    • 105.0~133.3ºC @ 100%RH

    • 110.0~140.0ºC @ 85%RH

    • 113.6~144.4ºC @ 75%RH

  • Temperature Control Accuracy: ±0.5ºC

  • Working Humidity Range: 75~100%RH

  • Humidity Control Accuracy: ±3%RH @ 85%RH

  • Working Pressure Range: 0.019~0.208MPa

  • Bias Terminals: 4

  • Multifunction LCD Display

  • 2 Control Mode: Unsaturated & Saturated

  • Continuous Operation: upto 300 hours

PCT Chambers

​Hirayama offer a range of fully saturated "PCT" Chambers.​

autoclaves

​PC242-HS-A

Table-top saturated pressure cooker.

  • Horizontal Chamber with Preheating

  • Outer Dimensions: W 505mm x D 535mm x H 380mm

  • Chamber Size (useable): ø170mm x D 310mm

  • Working Temperature Range: 100~134ºC

  • Temperature Accuracy: ±1.5ºC (100~104ºC), ±1.0ºC (105-134ºC)

  • Continuous Operation: Upto 200 hours

  • Maximum Useable Pressure: 0.206MPa

  • Bias Terminals: 4​

PC305SIII

  • Vertical Chamber with Preheating

  • Outer Dimensions: W 750 mm x D 550 mm x H 1050mm

  • Chamber Size (useable): ø220mm x D 340mm

  • Working Temperature Range: 105~158ºC

  • Temperature Accuracy: ±1.0ºC

  • Continuous Operation: Upto 500 hours

  • Useable Pressure Range: 0.019~0.490MPa

  • Bias Terminals: 4​​

PC362M

NEW Style saturated pressure cooker

  • Vertical Chamber with Preheating

    • Dew Fall Prevention mode prevents moisture formation on samples during preheat

  • Innovative Electronic Clamping Lid

    • Single button operation​

  • Outer Dimensions: W 600mm x D 697mm x H 1050mm​

  • Chamber Size (useable): ø300mm x D 450mm

  • 32.6 ltr capacity in a very small footprint.

  • Working Temperature Range: 105~134ºC

  • Useable Pressure Range: 0.02~0.2MPa

  • Bias Terminals: 6

Laboratory and Medical Device Steriliser Autoclaves

​Hirayama offer a range of easy to use sterilisers for use in the laboratory​​​​

sterilisers

HG-50 & HG-80 Steriliser Autoclaves

  • One Touch Lid - A single button press to open or close

  • Secure Lid Locking System

  • Large Operator Interface

  • Forced Air Cooling System

  • Effective capacities:

    • HG-50: 50.2 litres​

    • HG-80: 76 litres

  • Chamber Size (useable):​

    • HG-50: ø364mm x H 482mm​

    • HG-80: ø364mm x H 730mm

  • Maximum Steriliser Temperature: 135ºC​

  • Process Modes: 4​​​

HG/HGS/HGD-113/-133 range of Steriliser Autoclaves​

  • One Touch Lid - A single button press to open or close

  • Auto-slide Lid Locking System with adjustable temperature lock release setpoint

  • High Capacity Vertical Chambers with small footprint

    • ø500mm​

  • Available with separate Steam Generator (HGS & HGD models)​

  • Available with Vacuum Pump & Drying (HGD models)

  • Fast Cooling as standard

  • Programmable Auto-Start

  • Effective capacities:

    • HG-113: 108 litres​

    • HG-133: 129 litres

    • HGS-113: 113 litres

    • HGS-133: 133 litres

    • HGD-113: 113 litres

    • HGD-133: 133 litres

  • Maximum Steriliser Temperature: 135ºC​

  • 12 Programs​​​

HV-II & HV-IILB Series Steriliser Autoclaves

  • HV-II series for Class II controlled medical devices

  • HV-IILB series for laboratory use

  • Secure Lid Locking Mechanism with adjustable temperature lock release setpoint

  • Dual Interlock Mechanism - pressure & temp

  • Dual Sensing of residual air - Prevents sterilisation failure

  • Adjustable Exhaust Level

  • Optional Forced Cooling System

  • Programmable Auto Start

  • Effective Capacities:

    • HG-25II/25IILB: 25 litres​

    • HG-50II/50IILB: 50 litres

    • HG-85II/85IILB: 85 litres

    • HG-110II/110IILB: 110 litres

  • Air Removal Time:

    • HV-25II/25IILB & HV-50II/50IILB models:​ 3~9 minutes

    • HV-85II/85IILB & HV-110II/110IILB models: 6~18 minutes

  • Sterilisation Temperature Range:​

    • HV-25II/25IILB: 105ºC-126ºC variable​

    • HV-50II/50IILB: 105ºC-135ºC variable

    • HV-85II/85IILB: 105ºC-135ºC variable

    • HV-110II/110IILB: 105ºC-135ºC variable

Hirayama Manufacturing Corporation have been manufacturing Autoclaves, Environmental Pressure Chambers & Sterilisers in Japan since 1924.

​

They are a worldwide leader in their specific field and provide equipment to a wide range of industries from Medical to Semiconductors.

​

Hirayama's range of PCT and HAST chambers have been at the forefront of reliability testing for many years and have a wide install base within the UK.

​

PTS have been working with Hirayama since 1989 - with some staff members having worked with Hirayama equipment for upwards of 35 years.

​

Systems available for a wide range of application needs, including stand alone, dual chamber and benchtop models.